Intelligent production line
Dust thickness gauge
font: big in little    browse: 1307

Thickness gauge technical parameters
A, measuring range: 0-1250 / 3000 & mu; m(More than 1250 m to inform the factory in advance to be customized)
 B, the use of the environment: Temperature: 0 ℃ -50 ℃, humidity: 20% RH & mdash; 90% RH, no strong magnetic field environment
C, the thinnest substrate: 0.3mm
D, measurement accuracy:(1% - 3%)H 1.5 μ m
E, resolution: 0.1 & mu; m /1 μ m (100 μ m or less 0.1 μ m, 100 μ μ above is 1 μ m)
F, the smallest substrate area of ​​10 * 8mm
G, the smallest curvature: convex 5mm; concave 25mm
H, Dimensions: 130mm * 70mm * 24mm
I, weight: 100g
(Galvanized layer thickness gauge is also called the coating thickness gauge, galvanized layer thickness tester, galvanized tester, galvanized measuring instrument, paint thickness gauge, zinc tester) 
 DR360 coating thickness gauge is a method of application of electromagnetic induction methods, according to the national industry: GB / T 4956-1985 standard, a professional non-destructive testing instrument that is used to measure the thickness of the coating on the surface of magnetic metal materials and can measure non-destructively the thickness of the non-magnetic coating on the magnetic metal substrate (such as steel and iron) Such as: paint, electrophoresis, Fenwei, galvanized, chromium, imprison, enamel, rubber, enamel, coating, spray, paint, asphalt, thin fire coating, etc.) Easy to use, easy to carry, large LCD screen, Large-size, direct-reading backlight more clearly, the use of imported high-quality small metal probe, the structure of a solid and firm, better repeatability, better performance. The instrument is widely used in the coating industry, manufacturing, metal processing industry, Industrial, commodity inspection and other testing areas.  
 Instructions for using the instrument  
 After the instrument is installed on the battery, press "ON" / OFF "button to power on, wait for buzzer sound, the liquid crystal display shows" 0 ", the instrument automatically enters the measurement state, the probe will be directly vertical and quickly pressed to the workpiece surface coating, the instrument passed The probe automatically measures the thickness of the coating and displays the thickness through the display (note that the probe should be kept perpendicular when measuring)  
 Technical Parameters  
 A, measuring range: 0-1250 / 3000 m (more than 1250 m to inform the factory in advance to be customized)  
 B, the use of the environment: Temperature: 0 ℃ -50 ℃, humidity: 20% RH & mdash; 90% RH, no strong magnetic field environment  
 C, the thinnest substrate: 0.3mm  
 D, measurement accuracy: & plusmn;(1% - 3%)H 1.5 μ m  
 E, resolution: 0.1 & mu; m / 1 μ m (100 μ m or less is 0.1 μ m, 100 μ m or more is 1 μ m)  
 F, the smallest substrate area 10 * 8mm  
 G, the smallest curvature: convex 5mm; concave 25mm  
 H, Dimensions: 130mm * 70mm * 24mm   
 I, weight: 100g  
 J, power supply: three (7) alkaline batteries


© 2017 GuangZhou SANXIN Metal S&T Co., Ltd   粤ICP备09037207号